CDL Gateway™ - Allen Bradley - Engine/Generator Data in Allen Bradley PLC Data Map

By: Monico  12/08/2011

Beginning 3/31/10, all Gateways are now FLEX models that allow future addition of Input/Output modules.

SLC Version Available Ports & Protocols

DF1 Master over RS-232 via RJ-11 Jack

DH485 over RS-485 via RJ-45 Jack (2-wire or 4-wire) (Available Upon Request)

DF1 Master over Ethernet IP via RJ-45 Jack

DF1 Master Via PCCC/Ethernet/IP via RJ-45 Jack (For MicroLogix-Available Upon Request)

DF1 Master over RS-485 via RJ-45 Jack.(Available Upon Request)

ControlLogix Available Ports & Protocols

Controller Tags over RS-232 via RJ-11 Jack

Controller Tags over Ethernet IP via RJ-45 Jack

Features Include

User configurable port settings and addresses

Updates approximately 15-20 parameters per second

Integral 24 VDC power supply with Din-Rail Mounting

Pre-configured register data map.(Custom Mapping Available Upon Request)

32-bit values provided in consecutive integers AND floating point values for convenience

Integer Register blocks begin at N107:0000 and N109:0000 to avoid existing address conflicts

Controller Tag Versions can use the Tag Names specified in our Standard Data Map, or custom Tag Names can be Imported from CSV file

Allen-Bradley PLC Compatibility
Driver Name Compatible PLC Models
DF1 Master PLC-5 via Channel 0
DF1 Master MicroLogix Through AB programming cable
DF1 Master SLC
DF1 Master MicroLogix w/DB9 Port
DF1 Master over TCP/IP PLC-5, SLC 505
DF1 Master Via PCCC/EIP MicroLogix 1100, ENI Module
DH485 Master MicroLogix through AB programming cable
DH485 Master SLC
Ethernet IP Slave ControlLogix, CompactLogix
Controller Tags ControlLogix, CompactLogix

Downloads


Contact Monico

http://www.monicoinc.com

Email - none provided

Print this page

Other products and services from Monico

12/08/2011

CDL Gateway™ - Siemens PLC Version, Siemens PLC Data Map

All Gateways are now FLEX models that allow future addition of Input/Output modules. S7/S5 via PPI over RS-485 via RJ-45 Jack. S7/S5 via PPI over RS-232 via RJ-11 Jack. S7/S5 via TCP/IP thru RJ-45 Jack.


12/08/2011

CDL Gateway™ - BACnet Version

All Gateways are now FLEX models that allow future addition of Input/Output modules. Slave over Ethernet available upon request. UDP/IP Slave over Ethernet via RJ-45 Jack. MS/TP Slave over RS-232 via RJ-11 Jack.


12/08/2011

CDL Gateway™ - GE Fanuc Version, GE PLC Data Map

All Gateways are now FLEX models that allow future addition of Input/Output modules. SNP-X Master over RS-232 via RJ-11 Jack. TCP/IP Master via SRTP thru RJ-45 Jack. Series 90, VersaMax E05 CPU.


12/08/2011

CDL Gateway PLUS™ - Remotely Monitor & Control Industrial Engines, Generators, Compressors

All FLEX models are now C-UL approved for Class I Div II Groups A-D hazardous locations and UL-508 Listed for Industrial Control Panels. Accepts up to 2 GB Compact Flash memory card that will store up to 200 days worth of data in raw and CSV formats. Beginning 3/31/10, all standard Gateways are FLEX models, so I/O modules can be added at anytime. Time Manager to automatically sync the real time clock to a server or external source.


12/08/2011

Modbus Protocol, CDL Gateway™ - MONICO

The Modbus version of the Monico CDL Gateway™ is a complete solution for any Modbus protocol you will need. Since the CDL Gateway™ is a pre-configured product, field setup is minimal and programming is not required. With three ports to choose from you will have the right solution for your application in a single unit. Available in Input Registers or Holding Registers. Modbus TCP/IP Slave over Ethernet via RJ-45 Jack.


12/08/2011

Monico CDL Gateway™ - Communications Interface For Caterpillar® Industrial Engines & Generator Sets

If your application needs different address assignments, different protocols, or you have different controllers on the network you need to aggregate into our registers, we can quickly and efficiently accommodate your needs using our free software,MonicoView.