A.V.R.-Automatic Voltage Regulator

By: CHIN TAIRY ENTERPRISE CO., LTD. (A.V.R, I.V.R, Transformer, U.P.S, Oil Mist Collector with Air Cleaner)  10/16/2014
Keywords: Automatic Voltage Regulator

12 FEATURES 1. Input voltage range: ±15%~30% 2. The error of the output is less than ±1% 3. High overload capability: can resist above 150% overload without causing voltage to go down extremely. 4. Fastest reaction time: starts at 0.01 seconds, completing time only needs 0.1 second. 5. Output efficiency: Above 95% 6. Single module Design: easy to change the component s. 7. Main use H Class material: Prolong the usage time. 8. LED Display 9. Hidden NFB : Prevent man-made damage or machine suddenly being shut down. 10. Hidden cut-off Switch: Prevent man-made damage or machine suddenly being shut down. 11. Double layers glass fiber PCB: can prevent contact fault and prolong the usage time. 12. Central axle use aluminum material: prevent loosen and good for ventilation. 12 FUNCTIONS 1. Instant electricity shutdown delay protection. 2. R. S. T phase-shortage protection. 3. Excess High voltage protective function and abnormal wave function. 4. Excess Low voltage protective function. 5. CPU monitoring function. 6. Output voltage can be adjusted as requirement in a range of ±10% to satisfy the application of various machinery. 7. Overload productive function. 8. Short circuit protective function. 9. Adopting low-voltage start and machine start self detection. 10. Power abnormality Indication. 11. With Bypass switch switching. After start the bypass switch, AVR still have protective function. 12. One year guarantee of the components.

Keywords: Automatic Voltage Regulator

Contact CHIN TAIRY ENTERPRISE CO., LTD. (A.V.R, I.V.R, Transformer, U.P.S, Oil Mist Collector with Air Cleaner)

Email

Print this page

Other products and services from CHIN TAIRY ENTERPRISE CO., LTD. (A.V.R, I.V.R, Transformer, U.P.S, Oil Mist Collector with Air Cleaner)

power transformer from CHIN TAIRY ENTERPRISE CO., LTD. (A.V.R, I.V.R, Transformer,  U.P.S, Oil Mist Collector with Air Cleaner) thumbnail
10/16/2014

power transformer

1. Phase: Three phase 2. Nominal voltage: less then 600V for the first time, second times 3. Specifications: IEC762.EMC61000-6-4:2001 CAS:C22.2 NO.66-1988 U/L:506 4. Temperature limit: 60℃ (A Class), 80℃ (B Class), 120℃ (H Class) 5. Frequency: 50HZ/60HZ 6. Efficiency, copper loss, voltage regulation and impedance voltagetake 75℃ as the standard.


10/16/2014

U.P.S. Uninterruptible Power Supply

Static Type UPS (On Line) uses charger to offer battery electricity. Inverter produces sine AC for load. When AC is interrupted, inverter produces sine AC for load by battery. English LCD system, displaying UPS working flow chart, working value and guiding operating indication. Illustration by computer’s speech sound system. If the battery is over-discharged the life for normal use is then reduced; for the purpose of protecting the battery, which is provided with double check protects inclu