NF M 87-202 EIPF

By: caledonian cables ltd.  09/09/2015
Keywords: NF M 87-202 EIPF

Applications These NF M 87-202 EGSF instrumentation cables are used for safety extra-low use in petroleum and petrochemical units particularly for the transmission of a.c. or d.c. analogue signals, They are well adapted to underground use in industrial applications, in moist areas, where chemical and mechanical protection are needed. Construction: NF M 87-202 EGPF Conductor: Solid or Stranded copper conductor Insulation: PVC (70 mm maximum pair length) Individual Screen: Aluminium/polyester tape Individual Sheath: PVC Overall Binder Tape : Polyster tape Collective Screen: Aluminium/polyester tape Bedding: PVC LEAD Cover Inner Sheath: PVC Amouring: Double Steel Tape Outer Sheath: PVC Outer Sheath Colour: light-blue Core identification Colours Natural Red Blue Yellow 1 pair X X 1 triple X X X 1 quad X X X X Natural cores printed with pair/triple number Standards References: NF M 87-202 UTE C 32-014 NF C 32-020 IEC 60332-1 IEC 60332-3-24 Characteristics: Voltage Rationg:300/500V Operating Temperature:-40℃/+90℃ Installation Temperature: MAX+50℃ Maximum Voltage : 250V Voltage Test: 2000V Maximum conductor d.c. Resistance: Conductor Size Ohm/km at +20℃ 1/0.80mm(0.50 sqmm) 37.50 7/0.40mm(0.88 sqmm) 21.40 7/0.53mm(1.50 sqmm) 12.50 Capacitance between cond. (nf/km): 0.5 sqmm≤ 145 0.88 sqmm ≤160 1.50 sqmm ≤ 180 Type/codification: 1 Serie Number of pairs, triples or quads / 01 to 27 2 Serie Lay up in pair(IP) ,triple (IT) , quads (IQ) 3 Serie Core section 05 (0.5mm2) , 09 (0.88 mm2) or 15(1.5mm2) 4 Serie Overall screen(EG) or individual screen + overall screen(EI) 5 Serie Mechanical protection: without armour (SF), with armour (FA), with lead + armour(PF) Dimensions and Weight: NF M 87-202 Number of beams x cross section Cond. mm2 Outer Diameter(mm) Weight (kg/km) Min. Max. 03 IP 05 EIPF 3X2X0.5 0.50 17.1 19.6 950 07 IP 05 EIPF 7X2X0.5 0.50 21.8 25.0 1450 12 IP 05 EIPF 12X2X0.5 0.50 26.6 30.5 2025 19 IP 05 EIPF 19X2X0.5 0.50 31.6 36.3 2745 27 IP 05 EIPF 27X2X0.5 0.50 36.5 41.9 3400 03 IP 09 EIPF 3X2X0.88 0.88 19.5 22.3 1170 07 IP 09 EIPF 7X2X0.88 0.88 25.4 29.1 1810 12 IP 09 EIPF 12X2X0.88 0.88 31.6 36.3 2745 19 IP 09 EIPF 19X2X0.88 0.88 37.8 43.4 3770 27 IP 09 EIPF 27X2X0.88 0.88 43.9 50.4 4910 07 IT 05 EIPF 7X3X0.50 0.50 24.3 26.8 1549 12 IT 05 EIPF 12X3X0.50 0.50 29.3 32.3 2175 07 IT 09 EIPF 7X3X0.88 0.88 28.6 31.6 2074 12 IT 09 EIPF 12X3X0.88 0.88 34.7 38.3 1025

Keywords: NF M 87-202 EIPF

Contact caledonian cables ltd.

Email

Print this page

Other products and services from caledonian cables ltd.

09/09/2015

Flat Single Pair Glass Insulated

Application These cables are used with thermocouples for temperature measurements. Specification Conductor: Solid or stranded. Material is according to thermocouple


Central Loose Tube Cable from caledonian cables ltd. thumbnail
09/09/2015

Central Loose Tube Cable

Application This cable is characterized by light weight and small diameter, suitable for both aerial and duct installation. The cable


K23 LSZH Subway Signalling Cables for Metro/Local Trains/Tramlines from caledonian cables ltd. thumbnail
09/09/2015

K23 LSZH Subway Signalling Cables for Metro/Local Trains/Tramlines

Application The cables are designed for remote control and teletransmission in underground railway networks. The cables can be laid in


FIREROL FRL-SW-05M-OS/FRL-SW-1M-OS from caledonian cables ltd. thumbnail
09/09/2015

FIREROL FRL-SW-05M-OS/FRL-SW-1M-OS

Application -Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling


FLRY-A from caledonian cables ltd. thumbnail
09/09/2015

FLRY-A

Application This PVC insulated single-core cable with symmetrical conductor structure (type A) and thin wall is used for automobiles, motorcycles