MV KYN28C-12 Metal-clad Movable Switchgear

MV KYN28C-12 Metal-clad Movable Switchgear from Hebei Keneng Electric Co., Ltd.

By: Hebei Keneng Electric Co., Ltd.  08/16/2016
Keywords: Electric Power Distribution

MV KYN28C-12 Metal-clad Movable Switchgear - Miniaturization A MV KYN28C-12 metal-clad movable switchgear. MV KYN28C-12 metal-clad movable switchgear. MV KYN28C-12 metal-clad movable switchgear is the modification of MV KYN28A-12 metal-clad movable switchgear, so it not only has the advantages of MV KYN28A-12 metal-clad movable switchgear, but it also has other features shown below. The cabinet size: width: 650 mm, depth: 1200 mm, height: 2200 mm. And this kind of switchgear is smaller than other standard switchgears. It is equipped with ZN63K solid sealed polar pole type vacuum circuit breaker, and insulation performance is perfect. And this design solves the vacuum circuit breaker environment tolerance problem and it makes circuit breaker miniaturization and high-reliability come true. The rated current is 1250 A when the width of switchgear is 650 mm. If the rated current is larger than 1250 A, the width of switchgear should be larger than 650 mm. Both of current transformer and voltage transformer are manufactured of miniaturization and technical indicators meet standard requirements. And they can be installed in cabinet body properly. Pressure relief cover is designed of heat dissipation function, which is beneficial to in-time ventilation & heat dissipation. This design can also prevent dust effectively. Small bus-bar terminal and small bus-bar are our patented products, and their installation and overhaul are simple and convenient. Normal working conditions: Temperature range: -25 °C to +40 °C. The maximum daily average relative humidity: 95%. The maximum monthly average relative humidity: 90%. Altitude: ≤ 1000 m. Seismic intensity: ≤ 8 degree. Note: if the working condition is beyond the normal working conditions, please contact us before goods ordering. Special matters needing attention: The temperature of many regions in our country is high, and temperature fluctuation is fast, so switchgears are faced with the risk of condensation running in this kind of environment. Therefore, there are some matters needing attention in switchgears using process. Heaters should be put into operation as early as possible after switchgears are installed. Ensure heaters at running condition all day during switchgears standing by and running. Standard: MV KYN28-12 intelligent metal-clad switchgear and its main switches meet the standards as below: International standard: IEC 60694. IEC 62271-100. IEC 62271-102. IEC 62271-200. National standard: GB 1984. GB 3906. GB/T 11022. GB/T 16927.1. Technical parameters Items Parameters Rated voltage (kV) 12 Rated insulation level 1 min power frequency withstand voltage (kV) 42 Lightning impulse withstand voltage (kV) 75 Main bus-bar rated current (A) 630, 1250 Branch bus-bar rated current (A) 630, 1250 Rated short-time withstand current (kA) 16, 20, 25, 31.5 Rated peak withstand current (kA) 40, 50, 63, 80 Protection degree Enclosure: IP4X, opening: IP2X. Application of MV KYN28C-12 metal-clad movable switchgear: It is used for power plants, transformer substations, switching stations and main & auxiliary switch station. It is used for industries, such as paper-making, cement, textile, chemical engineering, food, automobile, petroleum and natural gas pipelines, metallurgy and mine. It is used for airports, ports, subways and railways. It is used for supermarkets, shopping centers, hospitals and basis & civilian facilities. You can contact us via [email protected], if you have any questions about our products.

Keywords: Electric Power Distribution

Contact Hebei Keneng Electric Co., Ltd.

Email

Print this page

Other products and services from Hebei Keneng Electric Co., Ltd.

GGD Low Voltage Distribution Switchgear from Hebei Keneng Electric Co., Ltd. thumbnail
08/17/2016

GGD Low Voltage Distribution Switchgear

GGD Low Voltage Distribution Switchgear with Good Breaking Capacity & Strong Applicability Several GGD low voltage distribution switchgears are in


MV HXGN-12/630-20 SF6 Insulated Compact Metal-enclosed RMU from Hebei Keneng Electric Co., Ltd. thumbnail
08/16/2016

MV HXGN-12/630-20 SF6 Insulated Compact Metal-enclosed RMU

MV HXGN-12/630-20 SF6 Insulated Compact Metal-enclosed RMU - Modularization Design A MV HXGN-12/630-20 SF6 insulated compact metal-enclosed RMU. MV HXGN-12/630-20


MV KYN28B-12 Metal-clad Movable Switchgear from Hebei Keneng Electric Co., Ltd. thumbnail
08/16/2016

MV KYN28B-12 Metal-clad Movable Switchgear

MV KYN28B-12 Metal-clad Movable Switchgear for Circuit Control, Protection and Monitor A MV KYN28B-12 metal-clad movable switchgear. MV KYN28B-12 metal-clad


MV KYN28A-12 (GZS1) Metal-clad Movable Switchgear from Hebei Keneng Electric Co., Ltd. thumbnail
08/16/2016

MV KYN28A-12 (GZS1) Metal-clad Movable Switchgear

MV KYN28A-12 (GZS1) Metal-clad Movable Switchgear with Advanced Interlocking Functions MV KYN28A-12 (GZS1) metal-clad movable switchgear is a three-phase, AC,


MV KYN28-12 Intelligent Metal-clad Switchgear from Hebei Keneng Electric Co., Ltd. thumbnail
08/16/2016

MV KYN28-12 Intelligent Metal-clad Switchgear

MV KYN28-12 Intelligent Metal-clad Switchgear for Chemical Engineering A MV KYN28-12 intelligent metal-clad switchgear. MV KYN28-12 intelligent metal-clad switchgear. MV


Switchgear from Hebei Keneng Electric Co., Ltd. thumbnail
08/16/2016

Switchgear

Switchgear is mainly used to control and protect electric equipment in electric power system electricity generation, transmission, distribution and electrical